• Solar Power Equipment Box-type Transformer(Prefabricated Substation)
Solar Power Equipment Box-type Transformer(Prefabricated Substation)
discuss personally
Model
SHN-1600-2
Basic info
Brand Vziman
Model NO. Solar Power Equipment Box-type Transformer
Rated voltage 33kV
Capacity 500kVA-1600kVA
Series Compact Substation
Product Detail

Product overview: 

  • A Solar Power Equipment Box-type Transformer that integrates 0.27kV 0.315kV 0.69kv voltage of grid-connected photovoltaic inverter into power grid output energy through a boost transformer.

  •  High-voltage switchgear, transformer body and protective fuse are centrally placed in the oil tank. High-voltage/low-voltage pre-installed substation is set up together with low-voltage switchgear and corresponding auxiliary equipment.

  •  Mainly used for small and medium-sized solar power generation.

  •  Execution standard: IEC61850 series, GB/T17467, etc.

Product advantages:

Leading technology:

  •  Standard anti-corrosion and salt spray environmental plan to meet the stringent environmental requirements of the site.

  •  Compact structure, small footprint, easy installation.

  •  Fully enclosed, fully insulated structure, safe and reliable operation.

  •  Easy to operate, maintenance-free, low equipment cost.

Enclosure:

  •  Adopt cold rolled high quality hot dip galvanized sheet.

  •  The surface is treated by electrostatic spray, and the paint can not be taken off for 50 years.

  •  Laser numerical control equipment cutting, drilling, bending, to ensure the processing accuracy.

  •  Product structure is divided into three parts: high voltage chamber, low voltage chamber and transformer.

  •  The cabinet is mainly pre-installed with: lightning arrester, load switch, transformer tap switch, protection fuse, oil level thermometer, oil level gauge, pressure relief valve, amount of oil discharge valve and other accessories.

  •  The low-voltage side is equipped with main circuit breaker, overvoltage protector, and can be designed and installed in complete sets of automatic measurement and intelligent control system.

  •  The transformer is a low loss oil-immersed transformer produced by WONE You Electric.

Functional units:

  •  Fully sealed structure, using the transformer insulating oil as the insulating medium and heat dissipation medium, overall has the advantages of compact structure, good heat dissipation performance.

  •  The high-voltage indoor door should be equipped with electromagnetic lock and live display. When the high-voltage side is live, the high-voltage chamber door cannot be opened.

  • The external door of the box transformer should be equipped with mechanical lock to meet the five requirements of high-pressure products and ensure personal safety.

 Components:

  •  Choose high-quality brand components such as Chint, Shanghai People Electric, Changshu Electric, etc.

  •  Schneider, ABB high-quality partners.

Supplementary material:

  •  High quality tin - plated busbar copper bar, with insulation sleeve.

  •  Hanhe cable is selected for secondary wiring.

 Processing and assembly:

  • Assembly workers have been trained for at least 6 months.

  • Secondary wiring is fully automatic equipment cutting to ensure reliable wiring.

  • Use power tools to ensure proper torque for bolting reinforcement.

  • The copper wire bus is NC punched and bent.

  • All kinds of experimental tests before leaving the factory to ensure normal operation.

Product parameters:

  • Voltage:0.69kV/33kV  0.69kV/11kV.

Conditions of use:

  •  Altitude: ≦2000m.

  • Ambient temperature range: -45℃ -- +45℃.

  • Outdoor wind speed: ≤35m/s.

  • Relative humidity: daily mean ≤95%, monthly mean ≤90%.

  • Installation location: Install in the place without fire, explosion risk, serious pollution, chemical corrosion and violent vibration.

  • If the above normal operating conditions are exceeded, customers can contact our company for customized solutions.

  • The above is suitable for 50/60Hz photovoltaic power generation system, the rated capacity of the transformer is 500~ 1600kVA.

Ordering instructions:

When ordering, the customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  •  Equipment layout drawing, combination drawing, floor plan drawing.

  • Brand, model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Device surface color.

  • Other special requirements can be negotiated with the manufacturer.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!